Optoelectronic Deflection Meter

Optoelectronic Deflection Meter
+
  • Optoelectronic Deflection Meter

The model ODM optoelectronic deflection meter is a long-distance non-contact 2D displacement measurement instrument. It utilizes an embedded system platform and a low-light COMS image sensor,combining advanced optoelectronic measurement algorithms to achieve high displacement measuring accuracy. It can perform real-time two-dimensional measurements with high measurement accuracy, a wide measurement range, compact size, high integration, and easy installation,among other characteristics. It's suitable for long-term, online, and multi-point automatic 2D displacement monitoring of structure for bridge,building, steel structures etc,.

Overview


The principle of optoelectronic deflection measurement is based on the installation of a target reflector (typically an infrared reflector) at the measurement location and creation of an optical marker point (marker) on the target. An optical system images this marker point onto a CCD receiving array. When the structures undergoes deflection or displacement, the target reflector moves accordingly. By measuring the change in the imaging position of the marker point on the CCD receiving array, the actual deflection or displacement of the structures can be calculated. This non-contact measurement method offers many advantages, including reduced interference and damage to the structure and the provision of high-precision measurement results.

 

 

Main functional characteristics

● Measuring distance, high measurement accuracy

●Simple installation, easy to use

● Measurement frequency up to 30HZ

● Intuitive data collection and analysis

 

Product application field

● Subway construction settlement monitoring

● Goaf settlement monitoring

● Bridge and tunnel settlement monitoring

● Water conservancy dam settlement monitoring

Specifications


Type

ODM-50

ODM-125

ODM-200

Target Requirements

Infrared target(850nm)

Infrared target(850nm)

Infrared target(850nm)

Measuring Distance

5m~120m

30m~200m

50m~300m

Measurement Accuracy

±0.3mm(@distance 35m)

±0.6mm(@distance 70m)

±1.2mm(@distance140m)

ImageSensor

COMS Low Light ImageSensors

Measurement Frequency

10Hz, Highest 30Hz(according to number oftargets varies)

Operating Voltage

DC12V

Communication Interface

RJ45

Power Consumption

6W

Operating Temperature

-20℃~70℃

Working Humidity

0%~95%RH

Size

175mm*95mm*250mm

Weight

1.2kg